Item Requirement Document · clause
Stair flight, detached house Width ≥ 700 mm TCVN 13967:2024, clause 5.11
Steps Tread ≥ 250 mm; riser 50–220 mm (preferably ≤ 190 mm); 550 mm ≤ 2h + b ≤ 700 mm TCVN 13967:2024, clause 5.11
Stairs in a townhouse Escape stair width ≥ 900 mm; tread ≥ 250 mm, riser ≤ 190 mm TCVN 9411:2012, clause 6.3.5.1
Headroom over stairs ≥ 2000 mm, measured vertically from the nosing or landing TCVN 13967:2024, clause 5.11
Guards on open sides of stairs and landings Height ≥ 900 mm; gaps ≤ 100 mm TCVN 13967:2024, clause 5.11
Clear room height Living rooms ≥ 2600 mm; kitchens and bathrooms ≥ 2300 mm TCVN 13967:2024, clause 5.9
Wet-area floors No standing water; fall ≥ 2 % to the drain TCVN 13967:2024, clause 5.13
Deep townhouses Deeper than 18 m must provide ventilation and daylight: open court, light well or skylight TCVN 9411:2012, clause 5.1.2
Walls on the plot boundary No doors, windows or vents; openings only where the wall is ≥ 2 m from the boundary TCVN 9411:2012, clause 6.4.3.1
Street-front balconies, townhouse Projection by street width: under 5 m: none; 5–7 m: 0.5 m; 7–12 m: 0.9 m; 12–15 m: 1.2 m; over 15 m: 1.4 m (1.2 m if the pavement is under 3 m) TCVN 9411:2012, clause 6.4.4.2, Table 2
Underside of balconies ≥ 3.5 m above the pavement TCVN 9411:2012, clause 6.4.4.3
Windows for daylight Window area 1/8 to 1/5 of floor area (recommended) TCVN 4451:2012, clause 7.3.3

QCVN are mandatory technical regulations; TCVN are voluntary standards unless a law or regulation refers to them. The detailed zoning plan of an area may be stricter — check it before applying for a permit.

Documents referenced

QCVN 01:2021/BXD
Construction planning — building coverage, setbacks and heights by plot and street.
QCVN 06:2022/BXD (Amendment 1:2023)
Fire safety for buildings — escape routes, stairs, stairwells.
TCVN 13967:2024
Detached houses — design requirements: stairs, heights, bathrooms, ventilation.
TCVN 9411:2012
Townhouses — design: ventilation of deep houses, boundary walls, balconies.
TCVN 4451:2012
Housing — basic design principles: daylight, ventilation, room layout.

How Home Check uses building codes

Codes of other countries: Singapore, Malaysia, Taiwan, Hong Kong

Code packs by country, where safety rules can only be stricter, never looser.

Building coverage ratioSetbackLight well

Do this for your own home in the app

Scan with your phone to get Home Check.

Markdown version of this page Index for machine readers (llms.txt)

Get Home Check

Scan with your phone to get Home Check.

The code opens the right store for your phone.

or

Download on the App Store Get it on Google Play

More